Xactimate Roofing Code Reference
What common Xactimate roofing line-item codes mean — not a price list (unit prices vary by region and carrier; ours is only an estimating aid, not a market quote).
- EXT GARGarage door panel, replace damaged section
- EXT SCRNWindow screen, replace damaged
- EXT SHTRVinyl shutter, paired window (replace damaged)
- EXT SIDINGVinyl siding, replace damaged panel
- GCGeneral contractor markup, supervision
- INS INSULBLBlown-in attic insulation, fiberglass or cellulose
- INT DRYDrywall ceiling repair, 1/2" — patch + finish
- INT PNTPaint ceiling, primer + two coats
- INT TXRTexture ceiling, knockdown or popcorn match
- OPOverhead & profit (10% + 10% — standard insurance markup)
- RFG 220Composition shingles, 3-tab, 20-year
- RFG 240Composition shingles, 3-tab/architectural, 30-year
- RFG 300Composition shingles, architectural/laminated, 40-50-year (premium)
- RFG CHIMChimney flashing kit (step + counter + cap)
- RFG CODE DECKDecking upgrade to current code (older roofs originally below code)
- RFG COUNTERFCounter-flashing, metal
- RFG DRIPEDrip edge, aluminum or galvanized
- RFG DSPDownspout, 2x3" aluminum
- RFG DSPLDownspout, 3x4" aluminum (oversized)
- RFG DUMPDump fee, roofing debris (per load)
- RFG FASCIAFascia board, primed pine or composite
- RFG FELT15Felt underlayment, 15-lb (#15)
- RFG FELT30Felt underlayment, 30-lb (#30)
- RFG GUT5Gutter, 5" K-style aluminum, including hangers
- RFG GUT6Gutter, 6" K-style aluminum (oversized), including hangers
- RFG GUTGRDGutter guard / leaf cover, snap-in
- RFG GUTRDGutter, round-back / half-round aluminum or copper
- RFG IWSIce & water shield self-adhering membrane underlayment
- RFG LBRRoofing labor, journeyman
- RFG MTLCLMetal roofing closure strip (foam or vented)
- RFG MTLEXPMetal roofing, exposed-fastener (R-panel / 5V)
- RFG MTLRIDMetal roofing ridge cap
- RFG MTLSSMetal roofing, standing seam, 24-gauge painted
- RFG MTLSTMetal roofing, stone-coated steel
- RFG OSB7-16OSB sheathing, 7/16" — roof deck replacement (material + install)
- RFG PERMITPermit, residential re-roof
- RFG PIPECOLLead pipe collar / jack (heavy-duty)
- RFG PLUMBPlumbing vent boot / pipe jack flashing
- RFG PLY1-2Plywood sheathing, 1/2" CDX — roof deck replacement
- RFG PLY5-8Plywood sheathing, 5/8" CDX — roof deck replacement
- RFG RIDGCRidge cap shingles, composition (asphalt)
- RFG RPGUTGutter repair, including hangers, seams, end caps
- RFG RPSEALRe-seal lifted shingles, apply roofing cement
- RFG RPSHGReplace individual damaged shingle (hail / wind spot repair)
- RFG RPSTEPReplace damaged step flashing (corroded / separated)
- RFG RPVALRepair section of valley flashing (rust / separation)
- RFG SKYSkylight, fixed, standard size (24x48)
- RFG SKYLSkylight flashing kit (replace existing)
- RFG SKYOSkylight, venting/operable, standard size
- RFG SLATESlate roofing, natural
- RFG SOFFITBDSoffit, aluminum or vinyl, vented
- RFG STARTERStarter row, asphalt shingle
- RFG STEPFStep flashing, sidewall (per piece)
- RFG SYNSynthetic underlayment (e.g. Tyvek, GAF Deck-Armor)
- RFG TARPTarp roof, temporary protection
- RFG TILECConcrete tile roofing
- RFG TILECYClay tile roofing (Spanish/mission)
- RFG TRPLTear off, haul, and dispose of composition shingles, 3-tab — labor only
- RFG TRPLLTear off, haul, and dispose of composition shingles, laminated — labor only
- RFG VALYValley flashing, open metal (W-valley)
- RFG VALYCValley flashing, closed-cut (woven shingles)
- RFG VENT SOFFITSoffit vent, continuous or strip
- RFG VENT TURBMushroom / turbine attic vent
- RFG VENTAContinuous ridge vent (attic ventilation)